Rx Viatrac 14 Plus Peripheral Dilatation Catheter
VASCULAR
hamburger

CONTROL AND DURABILITY

Rapid exchange system ideal for renal artery access and dilatation.

RAPID EXCHANGE

  • Rapid exchange delivery system for single operator use and fast balloon exchanges
  • Balloon lengths of 15 mm, 20 mm, 30 mm and 40 mm
  • Catheter lengths of 80 cm and 135 cm
  • 6F guide compatible across all balloon sizes and with shorter 130 cm guide wires

HIGH-PRESSURE STRENGTH

  • Durable XCELON balloon material with high RBPs of 14 atm for sizing flexibility
  • Advanced balloon processing designed for excellent rewrap and easy withdrawal

DELIVERABLE PERFORMANCE

  • Flexible distal catheter with tapered support mandrel inside catheter to improve pushability and kink resistance
  • Low profile design to cross tight lesions
  • Hydrophobic coated shaft and balloon to reduce friction

TECHNICAL SPECIFICATIONS

Rx Viatrac 14 Technical Specifications

COMPLIANCE CHART

Rx Viatrac 14 Technical Specifications

RX VIATRAC 14 PLUS - ORDERING INFORMATION

BALLOON DIAMETER
(mm)
BALLOON LENGTH (mm) STOCK NUMBER CATHETER
80 (cm) 135 (cm)
4.0 15 1008190-15 1008189-15
20 1008190-20 1008189-20
30 1008190-30 1008189-30
40 1008190-40 1008189-40
4.5 15 1008192-15 1008191-15
20 1008192-20 1008191-20
30 1008192-30 1008191-30
40 1008192-40 1008191-40
5.0 15 1008194-15 1008193-15
20 1008194-20 1008193-20
30 1008194-30 1008193-30
40 1008194-40 1008193-40
5.5 15 1008196-15 1008195-15
20 1008196-20 1008195-20
30 1008196-30 1008195-30
40 1008196-40 1008195-40
6.0 15 1008198-15 1008197-15
20 1008198-20 1008197-20
30 1008198-30 1008197-30
40 1008198-40 1008197-40
6.5 15 1008200-15 1008199-15
20 1008200-20 1008199-20
30 1008200-30 1008199-30
40 1008200-40 1008199-40
7.0 15 1008202-15 1008201-15
20 1008202-20 1008201-20
30 1008202-30 1008201-30
40 1008202-40 1008201-40
X
CLOSE
ORDERING INFO

PRODUCT INFO

Our online product catalogs provide the very latest information available, right at your fingertips. Download catalogs by product family in PDF format, or view the entire Abbott Vascular inventory in Excel. Product barcodes enable direct scanning for easy reordering.

INDICATIONS AND IMPORTANT SAFETY INFORMATION

rx-only-logo Viatrac™ 14 Plus Peripheral Dilatation Catheters

INDICATIONS

The VIATRAC 14 PLUS Peripheral Dilatation Catheter is intended:

  • To dilate stenosis in the peripheral arteries (iliac, femoral, ilio-femoral, popliteal, infra popliteal, renal arteries).
  • For the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae.

CONTRAINDICATIONS

None known for Percutaneous Transluminal Angioplasty (PTA).

WARNINGS

The Viatrac 14 Plus Peripheral Dilatation Catheter is not intended for use in the coronary arteries.

This device is intended for one-time use only. DO NOT resterilize and / or reuse it, as this can compromise device performance and increase the risk of cross contamination due to inappropriate reprocessing.

To reduce the potential for vessel damage, the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the stenosis.

When the catheter is exposed to the vascular system, it should be manipulated while under high-quality fluoroscopic observation. Do not advance or retract the catheter unless the balloon is fully deflated under vacuum. If resistance is met during manipulation, determine the cause of the resistance before proceeding.

Balloon pressure should not exceed the rated burst pressure (RBP). Refer to the product label for device specific information. The RBP is based on results of in vitro testing. At least 99.9% of the balloons (with a 95% confidence) will not burst at or below their RBP. Use of a pressure-monitoring device is recommended to prevent over-pressurization.

Use only the recommended balloon inflation medium. Never use air or any gaseous medium to inflate the balloon.

Use the catheter prior to the “Use by” date specified on the package.

Do not use, or attempt to straighten, a catheter if the shaft has become bent or kinked, as this may result in the shaft breaking. Instead, prepare a new catheter.

PRECAUTIONS

A thorough understanding of the principles, clinical applications, and risks associated with percutaneous transluminal angioplasty (PTA) is necessary before using this product.

Any use for procedures other than those indicated in these instructions is not recommended.

This device is not recommended for use in lesions that may require inflation higher than those recommended for this catheter.

Do not use if package is open or damaged.

Prior to angioplasty, the catheter should be examined to verify functionality and ensure that its size and shape are suitable for the specific procedure for which it is to be used.

During the procedure, appropriate anticoagulant therapy must be provided to the patient as needed. Anticoagulant therapy should be continued for a period of time to be determined by the physician after the procedure.

Shaft diameter differences should be taken into consideration when opening and tightening the hemostatic valve and upon withdrawal of the catheter.

It is important that the hemostatic valve (if used) is closed tightly enough to prevent blood leakage around the catheter shaft, yet not so tightly that it restricts the flow of contrast into and out of the balloon or restricts guide wire movement.

ADVERSE EVENTS

Potential adverse events include but are not limited to:

  • Abrupt closure
  • Allergic reaction (contrast medium; drug; device material)
  • Amputation or limb loss
  • Aneurysm or pseudoaneurysm in vessel or at vascular access site
  • Angina or coronary ischemia
  • Arrhythmia (including premature beats, bradycardia, atrial or ventricular tachycardia, atrial or ventricular fibrillation)
  • Arteriovenous fistula
  • Bleeding complications requiring transfusion or surgical intervention
  • Death
  • Detachment of a system component or implantation in an unintended site
  • Dialysis
  • Embolization (air, tissue, plaque, thrombotic material, device)
  • Emergent / urgent surgery
  • Fever
  • Heart failure
  • Hematoma or hemorrhagic event, with or without surgical repair
  • Hyperperfusion syndrome
  • Hypotension / hypertension
  • Infection
  • Ischemia or infarction not covered under other AEs
  • Myocardial infarction
  • Pain (leg, foot, and / or insertion site)
  • Peripheral nerve injury
  • Pulmonary embolism
  • Renal failure or insufficiency
  • Restenosis
  • Shock
  • Stent malapposition or migration, which may require emergency surgery to remove stent
  • Stent strut fracture
  • Stroke
  • Thrombosis or occlusion
  • Tissue necrosis or ulceration
  • Transient ischemic attack
  • Venous thromboembolism
  • Vessel dissection, perforation or rupture
  • Vessel spasm or recoil
  • Worsening claudication or rest pain

Prior to use, reference the Instructions for Use provided inside the product carton (when available) or at eifu.abbottvascular.com for more detailed information on Indications, Contraindications, Warnings, Precautions and Adverse Events.

AP2937831-WBU Rev. B

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

false
accessibility
© 2016 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?