OPTIS Integrated System
VASCULAR
hamburger
product photo

The OPTIS Integrated System allows for real time co-registration with table side control of OCT and physiology analysis. In addition to the workflow efficiencies offered by direct proximity, the on-demand availability of the OPTIS integrated system optimizes PCI workflow without adding significant time.

 

FOR CONFIDENCE IN HOW TO TREAT

The OPTIS integrated measurement system offers wireless fractional flow reserve (FFR) and optical coherence tomography (OCT) with seamless integration into the cath lab and PCI workflow.

  • Immediately access FFR and OCT during the percutaneous coronary intervention (PCI)
  • Control system functions in the sterile field and review images on the main cath lab monitor boom
  • Co-registration linkage between anatomical OCT image data on angiography images
  • Automated software features to inform all aspects of PCI planning

ADVANCED, HIGH-RESOLUTION IMAGING FOR UNPARALLELED VIEW OF VASCULATURE

Delivers OCT acquisition and rapid image processing within seconds

Real time co-registration offers side-by-side viewing of OCT intravascular imaging and angiography

  • Simultaneous angio and OCT image acquisition
  • Increases confidence in the relative position of angiographic and OCT image features

Software Features inform all aspects of PCI planning and decision making to establish the most optimal treatment strategies:

  • Lesion location and functional significance
  • Plaque morphology characterization to direct lesion preparation decisions
  • Exact stent sizing and placement via automated measurements
  • Optimal approaches to bifurcation stenting
  • Automated apposition and expansion evaluations for post-dilation decisions

 

ORDERING INFORMATION

Number Description
C408652 OPTIS Integrated System*

*The OPTIS integrated system is a customized product. Please contact your local sales representative for more information.

QUESTIONS?

We are proud of the quality of our products and services, and remain committed to providing exceptional support and assistance to our customers across the globe.

For ordering information,
visit ordering.

For technical issues and product questions of a technical nature, visit support.

INDICATIONS AND IMPORTANT SAFETY INFORMATION

rx-only-logo OptisTM

Integrated System, Mobile System, Software

INDICATIONS

The OPTIS Integrated System and Mobile System with OPTIS Software combined with Dragonfly™ DUO or Dragonfly™ OPTIS™ Imaging Catheter are intended for the imaging of coronary arteries and are indicated in patients who are candidates for transluminal interventional procedures. The Dragonfly DUO or Dragonfly OPTIS Imaging Catheter are intended for use in vessels 2.0 to 3.5 mm in diameter. The Dragonfly DUO, or Dragonfly OPTIS Imaging Catheter is not intended for use in the left main coronary artery or in a target vessel which has undergone a previous bypass procedure.

The OPTIS Integrated System and Mobile System will further acquire radio frequency signal outputs from both a distal intracoronary pressure transducer and a proximal aortic pressure transducer to determine the physiological parameter, Fractional Flow Reserve (FFR). The physician may use the FFR parameter, along with knowledge of patient history, medical expertise and clinical judgment to determine if therapeutic intervention is indicated.

CONTRAINDICATIONS

The OPTIS Integrated System and Mobile System with OPTIS Software are contraindicated where introduction of any catheter would constitute a threat to patient safety. Contraindications include:

  • Bacteremia or sepsis
  • Major coagulation system abnormalities
  • Patients diagnosed with coronary artery spasm
  • Patients disqualified for CABG surgery
  • Patients disqualified for PTCA
  • Severe hemodynamic instability or shock
  • Total occlusion
  • Large thrombus
  • Acute renal failure

NOTE: The system has no patient alarm functions. Do not use for cardiac monitoring.

WARNINGS

  • Appropriate anticoagulant and vasodilator therapy must be used during the procedure as needed.
  • Observe all advancement and movement of the Dragonfly Imaging Catheter under fluoroscopy. Always advance and withdraw the catheter slowly. Failure to observe device movement fluoroscopically may result in vessel injury or device damage.
  • Leave the guidewire engaged with the catheter at all times during use. Do not withdraw or advance the guidewire prior to withdrawing the catheter.
  • If resistance is encountered during advancement or withdrawal of the Dragonfly Imaging Catheter, stop manipulation and evaluate under fluoroscopy. If the cause of resistance cannot be determined or mitigated, carefully remove the catheter and guidewire together.
  • The catheter should never be forced into lumens that are narrower than the catheter body or forced through a tight or heavily calcified lesion.
  • The catheter should not be advanced through abnormally tortuous anatomy.
  • When advancing or retracting a catheter with a minirail tip through a stented vessel, the catheter may engage the stent between the junction of the catheter and guidewire, resulting in entrapment of catheter/guidewire, catheter tip separation, and/or stent dislocation.
  • Refer to the contrast media’s instructions-for-use for general warnings and precautions relating to use of the contrast media.

PRECAUTIONS

  • Safety and effectiveness have been established for the following patient population: adult patients undergoing non-emergent percutaneous coronary interventions in lesions with reference vessel diameters between 2.0 to 3.5 mm, which were not located in the left main coronary artery or in a target vessel which has undergone previous bypass procedures.
  • All operators must be trained prior to using the OPTIS Integrated System, the OPTIS Mobile System and the Dragonfly Imaging Catheter.
  • Only 100% contrast media is approved for human use.
  • Store the catheter at ambient temperature in a dry location out of direct sunlight.
  • Never attempt to attach or detach a catheter to the DOC while the “lock” LED is lit.
  • Do not kink, sharply bend, pinch, or crush the catheter at any time.
  • The catheter is for single use only. Do not reuse, re-sterilize, or reprocess.
  • The catheter is sterilized by ethylene oxide and is intended for one time use only. Non-pyrogenic. Do not use if the package is opened or damaged.
  • After use, the catheter may be a potential biohazard. Handle and dispose of in accordance with accepted medical practice and applicable laws and regulations.
  • The catheter has no user serviceable parts. Do not attempt to repair or alter any part of the catheter assembly as provided.

POTENTIAL ADVERSE EVENTS (AEs)

Potential complications which may be encountered during all catheterization procedures include, but are not limited to: acute myocardial infarction or unstable angina, allergic reaction to the contrast media, arterial dissection, injury, or perforation, cardiac arrhythmias, coronary artery spasm, embolism, thrombus formation, or death.


AP2946265-WBU Rev. A

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

false
accessibility
© 2016 Abbott. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company.

accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?